Punch list §25 item 4.3.5b complete.
sie.SEIE enabled, PLIC threshold/claim/complete wired into the trap
handler. Verified with a UART-loopback synthetic interrupt (PLIC has no
software set-pending register, unlike GICv2): claim_count=1, last_irq=10,
IIR confirms genuine receive-data cause, byte matched exactly. Self-test
code run once for evidence then fully reverted, per Captain Bob's ruling;
only the permanent substrate remains, no source enabled by default.
Three-arch acceptance boot clean, zero exceptions.